| LCR jack-in flat bag single plane dust remover |
The LCR jack-in type filter (origination jack-in filter) are the heavy load which and the high filtration rate needs for in the granular product's qigong conduction design. So long as filter inserts this the a silo, may link must unceasing carry on the air filtration. And maintains the very high dust collection efficiency, but not air transport influence. This kind filters the specification scope to expand unceasingly, at present has surpassed 120 kind of different filter, is suitable in processing, processes and stores the bulk freight and the powdery product and so on each kind of situation
The LCR jack-in type filter altogether have three kinds: H has oral may connect the ventilator or the eductor filter. This filter the weather effect, outside the indoor are not suitable. W has the cover filter. Uses in putting in the filter outdoor or exposes in the hostile environment the pressure system. F has the ventilator not the weather effect filter. Usually uses in the underpressure the situation also being possible to attach the damper which the like second page of institute shows. installs the position - - all Dalamatic jack-in type filter to be possible to demand wants the horizontal or the vertical stroke sets. In the air operated transmission system, the LCR jack-in type filter may insert in the silo and the tank's crown. This may cause the product and the transmission and the filtration air separates, thus prevents the product outflow and the dust gathers together dry. Collects the dust returns to directly the silo in the big collection vessel. LCR series B and W puts in generally the drum wind system, but F and H commonly used in needs to pull out the ventilator to reduce the pressure in the system. In machine in weapon transmission system, control as soon as, because loads and unloads, the transportation and the platoon sells goods the dust which Lu causes to be possible to use puts in seals up in box's LCR the series F filter. Collects the dust may return to the product directly, like this may save the space, but does not need to use the transmission pipeline and other supporting facilities, and has avoided dust which processing collects the question. The LCR jack-in type filter may also post need to carry on the dust control in the processing machinery, like the fluid bed reactor, the mixer, the mixer, grind waste and the grinder, or uses in the powder spray coating room, cutting the chartered airplane and each kind of similar machinery automatically and so on ventilates vent
LCR jack-in flat bag single plane dust remover performance chart
|
Dust removal model |
Filtration area m² |
Flat filter pocket
|
Approximate amount of wind m³ /h |
Is nervous and troubled the source pressure clear (KPa) |
Compressed air consumption quantity (cyclical 120 seconds) m³/h
|
Air blower |
Approximate weight (KG) |
|
Bag number |
Length (m) |
Code number |
Power (KW) |
|
LCR-4/7 |
4 |
6 |
0.7 |
700 |
450 |
4 |
F1(F1) |
258 |
|
SLCR-6/10 |
6 |
6 |
1.0 |
1000 |
450 |
4 |
F2(F1) |
265 |
|
LCR-7/7 |
7 |
10 |
0.7 |
1250 |
450 |
5 |
F3(F2) |
370 |
|
LCR-10/10 |
10 |
10 |
1.0 |
1750 |
450 |
5 |
F3(F2) |
382 |
|
LCR-8/7 |
8 |
12 |
0.7 |
1350 |
600 |
7 |
F3(F2) |
474 |
|
LCR-12/10 |
12 |
12 |
1.0 |
2000 |
600 |
7 |
F3(F4) |
488 |
|
LCR-14/7 |
14 |
20 |
0.7 |
2400 |
600 |
8.5 |
F4(F4) |
495 |
|
LCR-20/10 |
20 |
20 |
1.0 |
3500 |
600 |
8.5 |
F4 |
710 |
|
LCR-21/7 |
21 |
30 |
0.7 |
3600 |
600 |
10 |
F4 |
1090 |
|
LCR-30/10 |
30 |
30 |
1.0 |
5100 |
600 |
10 |
F5 |
1100 |
|
LCR-39/10 |
39 |
39 |
1.0 |
6500 |
600 |
13 |
F6 |
1250 | |
| Back |